54C75HT707500T – PP54C75L71-HO
Clear Liquids Pump with 5 inch suction and 4 inch discharge ANSI Flange connections. 7.5 inch impeller with 0.5 inch solid handling capability. Ductile Iron w/ CA6NM Impeller construction, Bareshaft configuration. Vacuum-Assisted Priming.
| Item: | 54C75HT707500T |
| Model: | PP54C75L71-HO |
Ratings |
|
| BEP at Maximum Operating Speed | 197 ft / 60.05 m |
Operation |
|
| Max. Flow Rate - 60 Hz | 1300 gpm / 295.26 m³/h |
| BEP Flow Rate at Maximum Operating Speed | 815 gpm / 185.11 m³/h |
| Max. Head - 60 Hz | 250 ft / 76.2 m |
| Max. Solid Handling Size | 0.5 " / 1.27 cm |
| Best Efficiency Point - 60 Hz | 77 % |
| Maximum Operating Speed | 3600 rpm |
Liquid |
|
| Max. Fluid Temperature | 200 °F / 93.33 °C |
Materials of Construction |
|
| Volute Material | Ductile Iron |
| Impeller Type | Enclosed |
| Impeller Material | CA6NM Stainless Steel |
| Bearing Frame Lubrication Type | Oil |
| Seal Material | Silicon Carbide / Tungsten Carbide / FKM / SS |
| Seal Type | Mechanical Seal |
| O-ring Material | Viton |
| Pump Shaft Material | 17-4 PH Stainless Steel |
| Wear Ring Material | ASTM A48 Class 40 Gray Iron |
| Priming Type | Pioneer Prime |
Dimensions |
|
| Discharge Type | Flat Face Flange - ANSI 150 |
| Discharge | 4 " |
| Impeller Dia. | 7.5 " / 191 mm |
| Suction | 5 " |
| Suction Type | Flat Faced Flange - ANSI 150 |
| SAE Size | None |
Other |
|
| Warranty Standard Time | 24 Months |
Performance Curve
Note: Curve does not account for priming system losses. Refer to FE Select to specify system conditions